FTP Shielded Alarm Security Cable,
For Security Alert,
Factory Supply, Low price,
Quick Delievery, Free Sample,
OEM is ok.
FTP Shielded Alarm Security Cable
Specifications
Fire Resistant Silicone Rubber Insulation
Red Low smoke Halogen Free PVC sheath
Al Foil Screen
Tinned Copper Drain Wire
Fire Resistant Cable Silicone Insulation
Applications
Cables are designed, manufactured and tested for general application in power supply and signal wiring, for emergency circuit and fire circuit control.
Operating temperature
-40°C to +90°C
(for insulated conductors only: max 200°C).
Minimum bending radius
10 times the outer diameter.
Cable construction
Conductors
Plain annealed copper wire, stranded according to EN 60228 class 2.
Insulation
PVC/XLPE/Silicone Rubber/ FEP insulation
Cabling
Insulated cores are cabled together.
Screen
Aluminium Foil Screen Copper Tape Screen Copper Braid Screed
Outer sheath
LSZH thermoplastic material.
Colour red (other colours on request).
Applicable Standards
Fire resistant CEI 20-36/2-1 / EN 50200 (PH90) / IEC 60331-21
Flame retardant EN 60332-1-2 / IEC 60332-1-2
Fire retardant EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C)
Acid gas emission EN 50267-2-1 / IEC 60754-1
EN 50267-2-2 / IEC 60754-2
Smoke density EN 61034-2 / IEC 61034-2
Detail Specification Table
No. of Cores | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 | 4 |
Conductor Area (mm) | 1.0 | 1.5 | 2.5 | 4.0 | 1.0 | 1.5 | 2.5 | 1.0 | 1.5 | 2.5 |
No. of Wires | 1 | 1 | 7 | 7 | 1 | 1 | 7 | 1 | 1 | 7 |
Nominal Diametre of Conductor (mm) | 1.13 | 1.37 | 0.67 | 0.85 | 1.13 | 1.37 | 0.67 | 1.13 | 1.37 | 0.67 |
Nominal Insulation Thickness (mm) | 0.6 | 0.70 | 0.80 | 0.80 | 0.60 | 0.70 | 0.80 | 0.60 | 0.70 | 0.80 |
Nominal OD (mm) | 8.05 | 8.40 | 10.05 | 11.40 | 8.55 | 9.15 | 11.15 | 9.20 | 10.20 | 11.65 |
Min. Bend Radius (mm) | 50 | 60 | 70 | 80 | 60 | 70 | 80 | 60 | 70 | 80 |
Cable Weight (kg/km) | 79.80 | 98.30 | 146.40 | 213.50 | 93.60 | 121.00 | 178.80 | 120.10 | 148.20 | 210.70 |
Max Conductor Resist. 20oC ohm/km | 18.1 | 12.1 | 7.41 | 4.61 | 18.1 | 12.1 | 7.41 | 18.1 | 12.1 | 7.41 |
Max Conductor Resist. 70oC ohm/km | 21.7 | 14.5 | 8.8 | 5.5 | 21.7 | 14.5 | 8.8 | 21.7 | 14.5 | 8.8 |
Capacitance (Adjacent Cores) PF/km | 85 | 95 | 100 | 100 | 85 | 95 | 100 | 85 | 95 | 100 |
Capacitance (Core to Screen) PF/km | 170 | 180 | 190 | 190 | 170 | 180 | 190 | 170 | 180 | 190 |
Area mm2 | Conductor No. of strands (mm) | Nominal Cable Diametre (mm) | Conductor Resistance ohm/km @20oc |
1.5 | 7 / 0.53 | 3.3 | 12.1 |
2.5 | 7 / 0.67 | 3.75 | 7.41 |
4.0 | 7 / 0.85 | 4.3 | 4.61 |
6.0 | 7 / 1.04 | 5.0 | 3.08 |
10.0 | 7 / 1.35 | 6.8 | 1.83 |
16.0 | 7 / 1.70 | 8 | 1.15 |